Gas and oil heaters
Heaters oil/gas bEST 135
The bEST 135 flue gas heater with a nominal heat output of133 kW, and an output of 121 kW. The efficiency is 91%, with an air flow rateof 11,000 m³/h.
Available static pressure is 0.2 mbar.
400 V power supply with 2 kW. Flue outlet Ø 200 mm , effective working range 43m.
By replacing the burner, it can change the fuel source it is supplied with fromoil to gas (natural gas, LPG) and vice versa.
Its construction is made of corrosion-resistant steel
Equipped with sturdy hooks for ceilingmounting and stainless steel feet for handling and floor installation
The bEST 135 heater has the option of connecting a thermostat
Gas heater BH with flue gas exhaust
- thanks to the closed combustion chamber no flue gases reach the house air and it remains free of excess carbon dioxide CO2
- exhaust gases are guided towards outside instead of to the area occupied by animals
- can be fueled by natural gas, propane or fuel oil
- does not increase the humidity level of the air and litter
- special switch to work only as an recirculation fan in hot period
- with the possibility of suspending
- connectable to a thermostat, humidistat, time control and to the climate computer of livestock houses
Construction of BH heaters
- stainless steel body and combustion chamber
- the flame monitored by the ionization electrode
- gas heaters equipped with: gas safety box with gas filter, pressure reducer, safety solenoid valve, slow action work solenoid valve, stabilizer, gas pressure connections - safety overheating manual reset thermostat
- low-voltage control
- easy access for maintenance and burner replacement
- IP65 protection class of electric board
- the built-in fan provides a wide throwing range and distributes the warm air in the house
Technical specifications - model BH100 gas
Rated heat power: 94,63kW/ 81,382kcal/h (natural gas); 97,89kW /84,187 kcal/h (LPG)
Output heat power: 85,36kW / 73,406 kcal/h (natural gas); 88,30kW, 75,937kcal/h (LPG)
Inlet pressure natural gas G20: 20 mbar
Inlet pressure LPG G31: 30-37 mbar
Natural gas consumption G20: 8.767 m3/h
LPG consumption G31: 3.54 m3/h
Heat efficiency: 90,2%
Airflow: 7.500 m3/h
Power supply: 230 V, 50Hz
Power consumption: 1.200 W
Net / gross weight: 135 kg / 153 kg
Technical specification - model BH50 gas
Rated heat power: 50,08kW / 43,073kcal/h (natural gas G20); 49.98kW /42,979kcal/h (LPG G31)
Output heat power: 45,08kW/ 38,766kcal/h; 45,23kW/ 38,896kcal/h
Heat efficiency: 90% (natural gas); 90,05% (LPG)
Inlet pressure: 20mbar (natural gas G20), 30/37mbar (LPG G31)
Gas consumption: 4.554m3/h (natural gas G20), 1.83m3/h-3.67kg/h (LPG G31)
Air flow: 4.100m3/h
Power supply: 230V, 50Hz
Power consumption: 800W, 3.85A
Weight: 75 kg net / gross 85 kg
Flue gas exhaust
Additional stainless steel exhaust chimney fi 150mm can be assembled from the elements:
1. One-sided muffled pipe 1m long (product code: 8218)
2. Elbow 90o(product code: 8221)
3. Chimney pot (product code: 8220)
4. Chimney pot with wind protection (product code: 8224)
5. Roof passage(product code: 8219)
6. Rain cowl (product code: 8223)
7. Mounting bracket (product code: 8230)
8. Double-sided muffled tee (product code: 8232)
9. Washout hole bottom (product code: 8233)
Ermaf heaters without flue gas exhaust
- with direct, open combustion chamber
- high efficiency with low level of exhaust fumes into the house
- fuelled by natural gas or propane (after replacement of nozzle and gas regulator)
- protection in the form of built-in solenoid valves which switch off the device in the event of a sudden rise in temperature or lack of gas
- electric flame burners with ionic flame protection in the combustion chamber
- stainless steel body resistant to aggressive conditions in livestock house and combustion chamber made of heat-resistant steel
Ermaf RGA 100 flue gas heater
- due the closed combustion chamber no flue gases reach the house air and it remains free of excess carbon dioxide CO2
- the exhaust gases are guided outside through the chimney
- stainless steel body
- the possibility of automatic climate computer control
- overheating safety